Vacuflo 960 Motor
Double-check the Motor Number Before you Purchase.
Please Call
Ametek-Lamb recommends replacing your carbon brushes and motor gaskets routinely to prolong the life of your new motor. Stock up now, have your supplies on hand.
As Simple As 1-2-3
The 117549-12 is a powerful 120V, 2-stage central vacuum motor designed to deliver strong and dependable vacuum performance. Featuring a large 7.2-inch fan, bypass motor design, tangential air discharge, and ball-bearing construction, this motor is built for demanding central vacuum applications.
The motor produces approximately 111 CFM, 125.4 inches of waterlift, and 483 Air Watts, providing the airflow and suction necessary for whole-home central vacuum cleaning.
Designed for the VACUFLO 960
The VACUFLO 960 is a dual-motor central vacuum system and requires two motors for a complete motor replacement.
The Ametek-Lamb 117549-12 provides the power and airflow required by the VACUFLO 960. If only one motor has failed, a single replacement may be sufficient. If both motors are worn or failing, replacing both at the same time can help maintain balanced system performance.
Quantity required for complete replacement: 2 motors.
Powerful 2-Stage Bypass Motor
The 117549-12 features a 2-stage motor design with a large 7.2-inch fan. Its bypass configuration separates the motor's cooling airflow from the dirt-laden air moving through the vacuum system.
This helps protect the motor while providing strong suction for residential central vacuum cleaning.
The tangential air discharge directs exhaust air away from the motor, while ball-bearing construction provides smooth and dependable operation.
Key Features
- Replacement motor for VACUFLO 960
- Ametek-Lamb 117549-12
- 120V operation
- Powerful 2-stage motor
- Large 7.2-inch fan
- Bypass motor design
- Tangential air discharge
- Ball-bearing construction
- Approximately 111 CFM
- Approximately 125.4 inches of waterlift
- Approximately 483 Air Watts
- Uses 833450-57 carbon brushes
- Two motors required for complete VACUFLO 960 motor replacement
Signs Your VACUFLO 960 Motor May Need Replacement
Over time, central vacuum motors can wear out. A failing motor may cause:
- Reduced suction
- Weak cleaning performance
- Excessive motor noise
- Increased vibration
- Motor overheating
- Motor shutting off during operation
- Motor failing to start
- Burning or electrical odor
- Excessive sparking
- Circuit breaker tripping
Before replacing a motor, check the hose, inlet valves, tubing, filter, and other components for blockages or restrictions. A clogged system can also cause reduced suction.
Two Motors Required for VACUFLO 960
The VACUFLO 960 uses two Ametek-Lamb motors.
For a complete motor replacement:
2 × Ametek-Lamb 117549-12
If only one motor has failed, replacing one motor may restore operation. However, if both motors have similar operating hours and show signs of wear, replacing both at the same time may be beneficial.
| Replacement Part Type | Motors |
|---|---|
| Voltage | 120 |
| Carbon Brush | 33450-2 Replaced by 833450-57 |
| Motor Stages | 2 |
| Motor Speeds | 1 |
| Motor Type | Series Universal |
| Motor Frequency | 50/60Hz |
| Motor Fan Diameter | 7.200 |
| Fan System Style | Bypass |
| Air Discharge | Tangential |
| Motor Low Temp | 32 |
| Motor High Temp | 104 |
| Motor Bearing | Ball |
| Motor Comm Bracket Material | Aluminum |
| Motor Fan Bracket Material | Aluminum |
| Motor Insulation Class | A |
| Motor Fan Shell Coat | none |
| Motor Duty Cycle | Intermittent |
| Motor Electrical Connection | Lead Wires |
| Weight (lbs) | 6.000000 |
Read about the 117549-12 Ametek Lamb Motor
The 117549-12 is a powerful 120V, 2-stage central vacuum motor designed to deliver strong and dependable vacuum performance. Featuring a large 7.2-inch fan, bypass motor design, tangential air discharge, and ball-bearing construction, this motor is built for demanding central vacuum applications.
The motor produces approximately 111 CFM, 125.4 inches of waterlift, and 483 Air Watts, providing the airflow and suction necessary for whole-home central vacuum cleaning.
Designed for the VACUFLO 960
The VACUFLO 960 is a dual-motor central vacuum system and requires two motors for a complete motor replacement.
The Ametek-Lamb 117549-12 provides the power and airflow required by the VACUFLO 960. If only one motor has failed, a single replacement may be sufficient. If both motors are worn or failing, replacing both at the same time can help maintain balanced system performance.
Quantity required for complete replacement: 2 motors.
Powerful 2-Stage Bypass Motor
The 117549-12 features a 2-stage motor design with a large 7.2-inch fan. Its bypass configuration separates the motor's cooling airflow from the dirt-laden air moving through the vacuum system.
This helps protect the motor while providing strong suction for residential central vacuum cleaning.
The tangential air discharge directs exhaust air away from the motor, while ball-bearing construction provides smooth and dependable operation.
Key Features
- Replacement motor for VACUFLO 960
- Ametek-Lamb 117549-12
- 120V operation
- Powerful 2-stage motor
- Large 7.2-inch fan
- Bypass motor design
- Tangential air discharge
- Ball-bearing construction
- Approximately 111 CFM
- Approximately 125.4 inches of waterlift
- Approximately 483 Air Watts
- Uses 833450-57 carbon brushes
- Two motors required for complete VACUFLO 960 motor replacement
Signs Your VACUFLO 960 Motor May Need Replacement
Over time, central vacuum motors can wear out. A failing motor may cause:
- Reduced suction
- Weak cleaning performance
- Excessive motor noise
- Increased vibration
- Motor overheating
- Motor shutting off during operation
- Motor failing to start
- Burning or electrical odor
- Excessive sparking
- Circuit breaker tripping
Before replacing a motor, check the hose, inlet valves, tubing, filter, and other components for blockages or restrictions. A clogged system can also cause reduced suction.
Two Motors Required for VACUFLO 960
The VACUFLO 960 uses two Ametek-Lamb motors.
For a complete motor replacement:
2 × Ametek-Lamb 117549-12
If only one motor has failed, replacing one motor may restore operation. However, if both motors have similar operating hours and show signs of wear, replacing both at the same time may be beneficial.
-
-20%
FlipBUS Central Vacuum Cleaning Balls
Was $62.75
Save $12.80 (20%) through 09/04/2026
Save: 20%
On Sale: $49.95
Save $12.80 through 09/04/2026$49.95
-
-10%
Tornado Power Central Vacuum Maintenance Cloths
Was $29.95
Save $3.00 (10%) through 09/04/2026
Save: 10%
On Sale: $26.95
Save $3.00 through 09/04/2026$26.95



Log In
Create New Account